The Creature Corner

Start here

Build the dry-bed sliding enclosure

96 × 24 × 24 in
(2438.4 × 609.6 × 609.6 mm)
· N11 illustrated plan

Choose an exterior finish

See the grain and color on this enclosure.

96 × 24 × 24-inch sliding enclosure with maple exterior veneer
Maple veneer · Select the picture to enlarge

Finish preview: veneer covers the wooden exterior, roof and exposed edges. This full wrap needs revised veneer quantities, core cuts and door clearances before construction; it is not included in this guide’s cut list. Natural grain and color vary by sheet.

About these previews

Rendered from this enclosure’s own construction model, using maple, white oak or walnut textures on the exterior surfaces. Added veneer and edge-band thickness is not modeled here. Construction steps, dimensions, shopping quantities, PDF and 3D reference remain the reviewed guide. Confirm the selected veneer, adhesive, balanced panel treatment and hardware clearances in a coordinated construction revision before building the full wrap.

Texture scans by Jenelle van Heerden via Poly Haven: Maple, White oak, Walnut. CC0 texture license. The scans illustrate natural wood and are not samples from the veneer supplier’s current batch.

A picture-led plan for the wooden shell, four sliding glass panes and six replaceable screens. The solid supports stay at their purchased thickness. Follow the short numbered operations and open the workshop details when a step calls for them.

Indoor dry shell only. No wet basin, saturated substrate, stacking, casters, outdoor use, roof climbing or equipment supported by mesh.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20261 / 108

Follow the build in 3D

Complete enclosure

Complete N11 enclosure

More model controls

Select a part for its name and ID.

About the model

Temporary clamps and supports appear in the step pictures. Early cutting stages show finished-part references, not a moving cutter. Track internals and lock contours are schematic. Received-profile capture, locking and glazing trials are required. Both rear leaves slide in the open-door view after lock bodies are removed; carriers move at half speed. Roofs are removable, right first, while the frame stays fixed.

Guide downloads

Illustrated PDF · Exact cut list · Purchasing schedule · Fastener schedule · Drawing set · Construction model

Start here

Before you build

Before cutting: Stock, glazing and corrosion-compatibility holds remain open. Do not build from the reference hardware sizes.

This is an intermediate to advanced woodworking project. You need accurate sheet cuts, guided recesses, stopped drilling, long-assembly squaring and careful glazing. The pictures explain the work; they do not remove these skills.

What the size describesReference dimensions
Uncoated wooden body, W × D × H
96 × 24 × 24 in
(2438.4 × 609.6 × 609.6 mm)
Body with planned coating only
96.006 × 24.006 × 24.006 in
(2438.55 × 609.75 × 609.75 mm)
Clear shell before local obstructions
94.59375 × 22.59375 × 22.59375 in
(2402.68 × 573.88 × 573.88 mm)
Unobstructed floor between framing
91.59375 × 19.59375 in
(2326.48 × 497.68 mm)
Clear space above a 4 in dry bed
91.59375 × 19.59375 × 17.09375 in
(2326.48 × 497.68 × 434.18 mm)
Each wooden door opening
45.04688 × 13.09375 in
(1144.19 × 332.58 mm)
Conservative one-leaf access, each bay
21.17969 × 11.40625 in
(537.96 × 289.72 mm)
Full support footprint
96 × 24 in
(2438.4 × 609.6 mm)
Planning space for access
108 × 48 × 36 in
(2743.2 × 1219.2 × 914.4 mm)

Width is left-to-right while facing the front. Local screen rings, backers, channels and fixings reduce usable space in their locations. Pulls/locks project beyond the wooden body. Planning space is not a heat clearance.

Before purchasing: Confirm the smaller access openings suit your maintenance needs. The center post stays fixed. Obtain actual contents, full support and building-floor evidence separately. No capacity, species suitability or enclosure performance is established.
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20262 / 108

Find the next operation

Start here

Follow the numbered pictured actions in order. Exact buying, cuts and drilling details stay in the references so they do not crowd each step.

StageBegin here
Check and prepare
Build the wooden shell
Finish and fit the doors
Screens and final checks

Shopping (p. 37) · Cut list (p. 43) · Cutting layouts (p. 55) · Drawings (p. 66) · Drilling (p. 89) · Trial record (p. 103) · Installation record (p. 104)

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20263 / 108

Set up the workshop

Get ready

Use a flat 112 ×36 in (2844.8 ×914.4 mm) supported bench with a clear walk-around route and separate clean glass/curing area. Rehearse the actual tools and clamps on the dry assembly before glue.

Have readyPurpose
Tape, square, straightedge, caliper and moisture meter
Measure sound stock; record actual thickness and stabilized workshop conditions.
Supported saw and guides, blade suited to sheet stock
Rough cuts, finished square cuts and repeatable full-section crosscuts.
Guided router, straight bit, templates and chisel
Roof overlap, rib bearing seats and vent/ring openings.
Stopped drill, countersink, hand driver and actual trial bits
11/64 in #8 clearance;7/64 in starting #8 pilot;1/8 in #4 clearance and 1/16 in starting #4 pilot. Verify receiver trials.
Two clamps with≥98 in clear opening; four 30 in clamps; protective half-inch cauls
Long/depth squaring; actual jaw/throat/tool access must be rehearsed. Temporary braces retain loose walls.
Stable padded turning cradle and three helpers
Empty-shell inversion and supported handling; verify actual mass and helper capacity.
Metal cutting/deburring setup, mesh snips and wire gloves
Matched steel rails, chip cleanup and captured wire edges. No gloves near rotating cutters.
Glazing handling gear and supplier help
No drilling or sizing tempered panes in the workshop.
Abrasives, brushes, masking, ventilation and required PPE
Follow your actual tool manuals and product labels; keep adhesive/coating stages separate.

Active work time depends on skills and tools. Plan separate stock stabilization, trials, glue holds, finish cure and track/sealant cure. Do not infer a weekend completion time.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20264 / 108

Check and prepare · 1 OF 32

1. Check the delivered wood

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Caliper, tape, square, straightedge, moisture meter

Before you start: Do not start cutting from nominal labels.

Check the delivered wood. Picture explains the action; use the linked drawing for exact settings.

  1. Measure each sheet at several points. The reference plywood is 0.70312 in (17.86 mm). Enter the actual batch thickness in the source and regenerate the parts before cutting.
  2. Each sheet needs at least 96.3125 in (2446.34 mm) ×47.59375 in (1208.88 mm) before the stated squaring cuts. Check the complete layouts, including defects.
  3. Select straight, dry untreated boards:2 ×2 means actual 1.5 ×1.5 in;2 ×4 means actual 1.5 ×3.5 in. Reject splits, loose knots, wane and twisted bearing faces. Record dimensions and stable moisture readings for the workshop.

Check before continuing: Receiving record complete; layouts and regenerated dimensions agree with your actual material.

Watch out: A nominal 3/4 in label does not mean 0.750 in.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20265 / 108

Check and prepare · 2 OF 32

2. Check the sliding-door kit

Parts: Delivered kit and trial offcuts

Have ready: Matched track samples, scrap wood, caliper, lock and safety-glass sample

Before you start: Do not order glass before the full finished-frame trial.

Check the sliding-door kit. Picture explains the action; use the linked drawing for exact settings.

  1. Check 993 upper channels,999 lower rails,995 shoes and 997 carriers are the same steel Roll-Ezy system. Do not substitute plastic, aluminum or a different profile.
  2. Trial the actual shoe and scant 6 mm glass, both running lanes, cushions, removable lift blocks and 963L lock. Use a supplier-handled sample; do not force a pane into a channel.
  3. Reserve matching wood/metal offcuts for the glue and coating trials. Record actual lane sizes, lock projections and the removal sequence.

Check before continuing: The receiving worksheet identifies every delivered model and each unresolved measurement.

Watch out: Matching exterior sizes do not prove matching running channels.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20266 / 108

Check and prepare · 3 OF 32

3. Plan the three sheets

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Full cutting diagrams, measured saw kerf, supported saw setup

Before you start: Inspect defects before accepting the layout.

Plan the three sheets. Picture explains the action; use the linked drawing for exact settings.

  1. Lay out all rough blanks with the face-grain arrows. Sheet 1 holds the floor and back. Sheet 2 holds the left roof and side, all screen rings and the backer straps. Sheet 3 holds the right roof and side and the retaining face.
  2. Square the long reference edge and one end. The plan reserves 0.125 in (3.17 mm) at each edge and 0.125 in (3.17 mm) between cuts.
  3. Rip the listed rows first, then crosscut each row into blanks. Rip means make a piece narrower; crosscut means shorten it. Keep sound trial offcuts.

Check before continuing: Every rough blank fits its marked usable sheet; no grain direction is rotated.

Watch out: Do not subtract saw kerf from the required finished part.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20267 / 108

Check and prepare · 4 OF 32

4. Cut and label the plywood

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Supported saw, guides, square, pencil

Before you start: Support the full sheet and waste; follow your saw manual and keep hands out of the cut.

Cut and label the plywood. Picture explains the action; use the linked drawing for exact settings.

  1. Cut rough blanks in the planned sequence, then finish each to the exact cut schedule. Measure from the same square edges each time.
  2. Label the part ID, FRONT, BOTTOM and INSIDE before turning a piece over. Mark the reference face and the two measuring edges shown on its drawing.
  3. Match paired sides and roof depths within 0.010 in (0.254 mm). Panel length/width target is±1/64 in (±0.397 mm), subject to the tighter mating-part checks.

Check before continuing: Finished sizes, quantities and orientation agree with the cut list.

Watch out: A rough blank is not a finished cut.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20268 / 108

Check and prepare · 5 OF 32

5. Cut the solid supports

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Crosscut saw with stop/support, square, part labels

Before you start: Use a carrier or stop setup for short blocks; never hold them beside a moving blade.

Cut the solid supports. Picture explains the action; use the linked drawing for exact settings.

  1. Use the two 2 ×4 boards for the sill and header. Use the five 2 ×2 boards for posts, cleats, blocks and roof ribs.
  2. Follow the linear-stock diagrams, including end squaring and kerf. Crosscut the long members before the small blocks.
  3. These supports retain their purchased thickness and width. No planing or resawing is specified. A different actual section requires recalculating the source.

Check before continuing: All members are square and correctly labeled; the bearing faces are sound.

Watch out: Do not buy shorter precut studs in place of 96 in boards.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 20269 / 108

Check and prepare · 6 OF 32

6. Check the square-edged back

Parts: L side P03L · R side P03R · Full back P04

Have ready: Tape, square, flat supported bench, clamps and spacers

Before you start: Keep the rear edges of both sides square. Do not rout a back recess.

Check the square-edged back. Picture explains the action; use the linked drawing for exact settings.

  1. Set the sides at the floor edges and support them with clamps. The back fits BETWEEN the sides, with its outer face flush with their rear edges.
  2. For the reference plywood batch, the back is 94 19/32 in (2402.68 mm) wide and 22 19/32 in (573.88 mm) high. Confirm the measured clear distance between the sides before assembly; do not force an oversize back.
  3. Keep the back bottom level with both side bottoms. The rear posts and rails support the back fastening; screws do not go into the plywood edges.

Check before continuing: Both rear corners meet squarely with no step or recess in either side. All three panel bottoms line up.

Watch out: Measure between the inside side faces, not across their outside edges.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202610 / 108

Check and prepare · 7 OF 32

7. Prepare the roof-rib seats

Parts: Front sill S01 · Front header S02 · Upper back rail S50T · Roof rib 1 S601 · Roof rib 2 S602 · Roof rib 3 S603

Have ready: Guided router, square, chisel, stop setup

Before you start: Trial one complete bearing joint before machining the six ends.

Prepare the roof-rib seats. Picture explains the action; use the linked drawing for exact settings.

  1. Mark the three rib centers from the left body datum:25,48 and 71 in (635,1219.2 and 1803.4 mm). Use the exact seat positions on the member drawings.
  2. Make each rail seat 0.5 in (12.7 mm) into its width and 0.75 in (19.05 mm) down from its top. Remove the lower 0.75 in from the last 0.5 in of each rib end.
  3. The remaining upper end rests on the seat floor. Check the rib tops finish level with the supporting rails; drill only after the clamped dry fit.

Check before continuing: All six ends bear fully; none hangs from a screw alone.

Watch out: Do not reverse an end notch or cut the entire rib end away.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202611 / 108

Check and prepare · 8 OF 32

8. Make the roof overlap

Parts: Left roof P02L · Right roof P02R

Have ready: Guided router, depth measurement, offcut coating trial

Before you start: Confirm the left/right labels before removing either face.

Make the roof overlap. Picture explains the action; use the linked drawing for exact settings.

  1. At the center seam, leave the LEFT lower tongue and RIGHT upper tongue. The overlap is 0.5 in (12.7 mm). Use the exact face/depth settings in the machining reference.
  2. The nominal removal is 0.36156 in (9.18 mm) deep. Its allowance leaves room for finish; trial both coated offcuts first.
  3. Keep the outside roof faces level when seated. The roofs remain removable. Do not glue the overlap or drive screws through its thin tongues.

Check before continuing: The cured sample slides together without force and leaves no more than 1/32 in (0.794 mm) local seated gap.

Watch out: Removing the same face from both halves makes a step instead of an overlap.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202612 / 108

Check and prepare · 9 OF 32

9. Cut the vent and ring openings

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Guided router/jigsaw, templates, square, support

Before you start: Keep the cutout supported. Cut-wire handling comes later.

Cut the vent and ring openings. Picture explains the action; use the linked drawing for exact settings.

  1. Mark the side vent from the wall FRONT edge: 3.75 in (95.25 mm). Mark its bottom 7 in (177.8 mm) above the finished wall bottom. Each side opening is 16.5 in (419.1 mm) ×4 in (101.6 mm).
  2. Mark the four 19 ×16 in (482.6 ×406.4 mm) roof openings using the roof drawings. Preserve the center overlap and all webs.
  3. Cut matching through-openings in the six one-piece screen rings. Each ring overlaps its opening by 3/4 in (19.05 mm). Smooth and seal every cut edge later.

Check before continuing: Vent/ring pairs match, supports remain intact and no ring crosses a backer strap or roof rib.

Watch out: Do not enlarge openings into the frame or rib lands.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202613 / 108

Check and prepare · 10 OF 32

10. Trial the screws and mark holes

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Trial screws, stopped drill, clearance/pilot bits, clamps

Before you start: A clearance hole goes through the first piece; a pilot is the smaller hole in the receiving wood.

Trial the screws and mark holes. Picture explains the action; use the linked drawing for exact settings.

  1. Use the exact fastener schedule and drawing datums. Transfer receiver holes during the clamped dry fit; do not build a chain of hole-to-hole measurements.
  2. For #8 screws, start the receiving trial at 7/64 in (2.778 mm); clearance is 11/64 in (4.366 mm). Confirm with the real screw root and batch. Countersink only enough for a flush head.
  3. Limit each pilot to its listed depth. The schedule checks intermediate wood, joint pockets, screw length and at least 1/16 in (1.588 mm) remaining wood beyond the point in this candidate.

Check before continuing: The offcut joint closes without splitting, a buried point or a crushed veneer.

Watch out: A deep countersink can consume the remaining wood at a thin seat.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202614 / 108

Build the wooden shell · 11 OF 32

11. Dry-fit the complete wooden shell

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Flat 112 ×36 in bench, square, two≥98 in clamps, four 30 in clamps, protective cauls

Before you start: Have three people for large-piece handling. Keep walls clamped until the back/frame hold them.

Dry-fit the complete wooden shell. Picture explains the action; use the linked drawing for exact settings.

  1. Lay the floor on the fully supported bench. Set sides between floor and roof level; place the back between the square side edges, flush at the rear. Rehearse the front frame, blocks, ribs and removable roofs without glue.
  2. Use half-inch cauls to protect faces. Keep long clamps supported and move one clamp at a time to clear a drilling station. Rehearse the actual clamp jaws and tool body.
  3. Compare both top and front diagonals, measure each opening and check flatness. Project target: diagonal difference no more than 1/16 in (1.588 mm), with every joint fully seated.

Check before continuing: No part requires forcing; actual tool/clamp access and helper roles are rehearsed.

Watch out: Clamps can pull a wrong-sized assembly together while hiding a bad cut.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202615 / 108

Build the wooden shell · 12 OF 32

12. Fit the side cleats and rear posts

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Clamps, wood glue, stopped drill, W200 screws

Before you start: Glue only clean bare wood. Do not rely on glue as a certified structural adhesive.

Fit the side cleats and rear posts. Picture explains the action; use the linked drawing for exact settings.

  1. Clamp each side flat on the bench. Seat its upper/lower cleats and rear corner post in the locations on the part drawings, leaving the vent clear.
  2. Spread Titebond III on the mating faces and drive the listed screws from the outward side into the solid supports. Keep the heads flush.
  3. Set the sides on the floor with temporary braces. Keep the floor interface clamped and follow the measured dry-fit positions.

Check before continuing: Both sides have the same finished height and the rear posts leave a clear, square opening for the back.

Watch out: Do not coat glue lands or leave side walls standing unsupported.

Allow time: Manufacturer open assembly 8–10 min; total 20–25 min at 70°F/50%RH. Keep stressed joints clamped 24 h; do not stress a new joint for at least 24 h.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202616 / 108

Build the wooden shell · 13 OF 32

13. Fit the back and its rails

Parts: Full back P04 · Lower back rail S50B · Upper back rail S50T · Center back post S51

Have ready: Clamps, wood glue, W200 screws, square

Before you start: Support the back before loosening a wall brace.

Fit the back and its rails. Picture explains the action; use the linked drawing for exact settings.

  1. Clamp the two back rails and center back post to the back, using the drawing locations. Keep the rib seats facing upward.
  2. Glue the bare mating faces and fasten through the back into those solids. Set the back between the sides and onto the floor, with its inside face against the rear posts and its outside face flush with the side rear edges.
  3. Recheck diagonals before driving the screws into the rear corner posts. Use the listed offset stations so side and back screws do not meet.

Check before continuing: Back is flush at both rear corners, case square and all receiver pilots stop inside solid wood.

Watch out: Do not assume a thin removable back would supply this same racking path.

Allow time: Hold stressed glue joints 24 h, longer if actual label/environment requires.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202617 / 108

Build the wooden shell · 14 OF 32

14. Position the five sill blocks

Parts: Sill support block 1 S101 · Sill support block 2 S102 · Sill support block 3 S103 · Sill support block 4 S104 · Sill support block 5 S105 · Floor P01

Have ready: Square, clamps, wood glue, station drawing

Before you start: The floor remains clamped to the walls; underside fixings are installed at step 19.

Position the five sill blocks. Picture explains the action; use the linked drawing for exact settings.

  1. Locate the five short blocks from the floor left datum using their exact X coordinates. Their front faces align with the sill/front-frame recess.
  2. Glue their bare bottom faces to the floor and clamp them with the full floor supported. Block height is 2.5 in (63.5 mm).
  3. Use a straightedge across the tops. They must carry the sill together without rocking.

Check before continuing: All five bearing tops are level and their locations agree with the drawing.

Watch out: A block floating above the floor transfers no bearing load.

Allow time: Do not turn or stress the assembly until the glue hold is complete.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202618 / 108

Build the wooden shell · 15 OF 32

15. Lay out the front frame

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Flat bench, square, clamps, measuring tape

Before you start: Assemble this frame off the case so the backer holes are accessible.

Lay out the front frame. Picture explains the action; use the linked drawing for exact settings.

  1. Lay header and sill on their front faces with three posts between them. The header is above; the center post divides two equal openings.
  2. Set each opening to 45.04688 in (1144.19 mm) ×13.09375 in (332.58 mm). Check the entire frame length against the exact rail cut.
  3. Lay the six plywood backer straps on the exposed rear faces across each post joint. Mark their positions and transfer the four fixing holes per strap.

Check before continuing: Frame is square on the bench and all bearing ends touch.

Watch out: Do not install the frame first and discover the drill cannot reach an end strap.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202619 / 108

Build the wooden shell · 16 OF 32

16. Join the front frame

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Wood glue, clamps, W125 screws, stopped drill

Before you start: Leave the frame flat and clamped while drilling and driving.

Join the front frame. Picture explains the action; use the linked drawing for exact settings.

  1. Spread glue on the bare backer/contact faces. Bearing post ends remain seated against sill and header; the straps tie the joints together.
  2. Drive four #8 ×1.25 in screws per strap, using the exact schedule: two into the post and two into the rail. Recheck flush heads and pilot depths.
  3. Keep both opening diagonals matched as the glue sets. Lift the cured frame with a helper, supporting both bays.

Check before continuing: The cured frame retains two square openings without clamp pressure.

Watch out: Do not treat the glue label or this digital layout as a structural load rating.

Allow time: Keep stressed joints clamped 24 h; do not stress the frame sooner.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202620 / 108

Build the wooden shell · 17 OF 32

17. Fit the frame and retaining face

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Helpers, clamps, glue, W200 screws, square

Before you start: The center post is permanent. Keep all temporary supports until the frame is fixed.

Fit the frame and retaining face. Picture explains the action; use the linked drawing for exact settings.

  1. Seat the sill on all five blocks, with the frame ends between the sides. Use the rehearsed side fixing stations to locate the rails and end posts.
  2. Fit the retaining face across the floor front. Its reference height is 6 in (152.4 mm); glue the bare mating lands and screw into the sill and five blocks.
  3. Recheck body width, diagonals and both openings before glue cures. Side screws into rail ends locate the frame; no end-grain screw capacity is claimed.

Check before continuing: The retaining face has continuous upper support and five supported lower stations; the frame is square.

Watch out: Do not use the retaining board as a step or lifting handle.

Allow time: Keep clamped for the required glue hold before handling.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202621 / 108

Build the wooden shell · 18 OF 32

18. Seat the three roof ribs

Parts: Roof rib 1 S601 · Roof rib 2 S602 · Roof rib 3 S603 · Front header S02 · Upper back rail S50T

Have ready: Clamps, W125 screws, depth-stopped drill

Before you start: Do not overdrill the thin bearing ends or use the mesh as a support.

Seat the three roof ribs. Picture explains the action; use the linked drawing for exact settings.

  1. Place each rib’s notched ends on their matching header/back-rail seats. Tops align with the roof support plane.
  2. Drive one #8 ×1.25 in screw at each end, through the remaining 0.75 in rib end into 0.5 in receiving wood. Use the listed pilot depth and countersink trial.
  3. Dry-fit both roofs again. Confirm the screen rings clear the ribs and the right roof can lift free before the left.

Check before continuing: Six bearing ends fully seated; roofs lie flat without being forced down.

Watch out: A screw cannot replace a missing bearing seat.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202622 / 108

Build the wooden shell · 19 OF 32

19. Fasten the floor from above after turning

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Three helpers, clamped rigid cradle, bench, W200 screws

Before you start: Turn only the empty cured shell. Clamp the floor to the case before the turn.

Fasten the floor from above after turning. Picture explains the action; use the linked drawing for exact settings.

  1. Remove loose roofs and fittings. Put padded temporary cross supports on the bench at X13,48 and 83 in (330.2,1219.2 and 2108.2 mm). They span the header-to-back support plane.
  2. With three helpers, turn the clamped empty case upside down onto those supports. The fixed rim/ribs bear on the cradle; the floor underside faces upward. Prevent rolling and sliding with stops/clamps.
  3. Drive the listed floor screws downward from this exposed face into lower cleats, rear posts and five blocks. Check all buried points, then return the supported empty shell upright.

Check before continuing: Floor fixings are complete without drilling beneath a flat board or an unstable lifted case.

Watch out: Never attempt the turn with substrate, glass or loose roof panels installed.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202623 / 108

Finish and fit the doors · 20 OF 32

20. Prepare the wood for coating

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Abrasives 120–220, vacuum, masking, trial pieces

Before you start: Do not dismantle glued structural joints.

Prepare the wood for coating. Picture explains the action; use the linked drawing for exact settings.

  1. Remove the loose roofs and screen rings. Sand exposed wood progressively 120 to 220 grit; ease sharp edges lightly and clean dust from corners and holes.
  2. Mask the exact bare-wood steel-track bond lands on sill/header/jambs. Keep hardware, running surfaces and future adhesive contact clean.
  3. Test the selected coating and sealant on the actual wood and planned cleaner. Reject weak adhesion or incompatibility; record the accepted system.

Check before continuing: All cut edges and holes are accessible; masked bonding lands remain clean bare wood.

Watch out: Silicone contamination can prevent coating or adhesive from bonding.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202624 / 108

Finish and fit the doors · 21 OF 32

21. Coat the shell and let it cure

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Varathane 284473, synthetic brush, ventilation, film check

Before you start: Indoor dry use only. This coating is not a waterproof tank liner.

Coat the shell and let it cure. Picture explains the action; use the linked drawing for exact settings.

  1. Apply the selected finish to exposed faces, cut edges, holes and removable pieces. Stir, do not shake. Use the product’s thick even coat; target 9 mil wet to 3 mil dry rather than wiping on an unmeasured thin film.
  2. Apply two extra coats to the dry-basin contact faces only after the required recoat interval and 220-grit preparation. Keep masked track lands bare.
  3. Record temperature/humidity, last coat time and full-cure end. Keep coated roof samples: they must still fit without forcing.

Check before continuing: Coating is fully cured and the actual trial passes; odor or dry-to-touch alone is not acceptance.

Watch out: Do not substitute a mildew-additive outdoor finish or call low-VOC animal-safe.

Allow time: VAR-35: about 2 h recoat,48 h light handling,7 days full cure at 70°F/50%RH; cooler/damper conditions need longer. Follow the delivered label if it is more restrictive.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202625 / 108

Finish and fit the doors · 22 OF 32

22. Bond the matched tracks

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Deburred profiles, bare-wood bond lands, PL Premium 1390595, spacers, clamps

Before you start: Keep adhesive out of rolling channels. Do not drill fasteners through the anvils.

Bond the matched tracks. Picture explains the action; use the linked drawing for exact settings.

  1. Final-size the continuous rails and jamb channels against the finished frame at the named checkpoint. Keep reference end allowances and cured bond-bed thickness in the calculation.
  2. Clean wood/galvanized contact surfaces as the adhesive instructions require. Apply a continuous supporting bond; align upper/lower lanes vertically with the actual sample gauge.
  3. Brace the profiles without twisting them. Trial lock clearance and any required divider relief on a sample before altering the actual jamb.

Check before continuing: Both bays have straight aligned lanes and a recorded cured outside-face opening.

Watch out: A screw in a rolling path or a crooked lower rail can damage the shoe or glass.

Allow time: PL Premium: brace≥24 h; reserve 48 h at 78°F/50%RH before loading, longer if actual conditions require. Complete the real wood/metal bond trial.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202626 / 108

Finish and fit the doors · 23 OF 32

23. Measure the finished bays and order glass

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Actual cushions, tracks, lock, sample glass, caliper, fabricator order sheet

Before you start: Do not order from the reference pane dimensions alone.

Measure the finished bays and order glass. Picture explains the action; use the linked drawing for exact settings.

  1. Install/transfer the actual cushion tabs at the two jambs of each bay. Check the 963L clip and bar clear the delivered channels through the whole travel.
  2. Measure each cured track outside-face opening and each cushioned closing width. Pane width=(closing width+1 in overlap)/2; pane height=outside-face opening−1.25 in.
  3. Ask the fabricator to confirm scant 6 mm fit, tempering, polished edges, quantities and tolerances. Four reference panes are 22.89844 in (581.62 mm) wide ×11.78125 in (299.24 mm) high; no holes. Sign the actual order only after the trial.

Check before continuing: Fabricator-approved final dimensions and trial evidence are recorded for both bays.

Watch out: Tempered panes cannot be cut, drilled or ground to repair a bad order.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202627 / 108

Finish and fit the doors · 24 OF 32

24. Prepare the shoes and carriers

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Matching profiles, metal-cutting setup, deburring tools

Before you start: Do not substitute another shoe for scant 6 mm glass.

Prepare the shoes and carriers. Picture explains the action; use the linked drawing for exact settings.

  1. Cut each shoe to its actual accepted pane width and each carrier to(closing width+pane width)/2. Reference carrier length is 33.84766 in (859.73 mm).
  2. Deburr ends without distorting the running surfaces. Clean out metal chips before assembly.
  3. Set carriers and shoe seating as the KV instructions and sample trial require. A carrier rolls at half the pane travel; it is not a fixed rail.

Check before continuing: Four shoes and four carriers match the signed bay order and move freely on the trial.

Watch out: Do not trim a carrier to pane length.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202628 / 108

Finish and fit the doors · 25 OF 32

25. Fit the four glass panes

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Helpers, glazing handling gear, accepted matched profiles

Before you start: Protect glass edges. Keep lift blocks out until panes are safely seated.

Fit the four glass panes. Picture explains the action; use the linked drawing for exact settings.

  1. Use the fabricator-approved shoe seating method. Insert the rear leaf into its upper lane, lift only enough to clear the lower retaining lip, and settle it onto its carrier. Repeat for the front leaf.
  2. Fit both bays separately. Keep the agreed one-inch overlap and the closing stops; check metal never strikes an exposed glass edge.
  3. Slide slowly by hand through the accepted travel. Stop if a shoe catches, a carrier reaches an end or the frame flexes.

Check before continuing: All four panes are correctly supported, overlap at closing and travel without collision.

Watch out: Do not force a pane into a misaligned lane.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202629 / 108

Screens and final checks · 26 OF 32

26. Capture the side screens

Parts: L side mesh M01L · R side mesh M01R · L side screen ring V01L · R side screen ring V01R

Have ready: Mesh snips, wire-handling gloves, W125 screws, trial

Before you start: Wire gloves are for handling only; keep gloves away from rotating cutters.

Capture the side screens. Picture explains the action; use the linked drawing for exact settings.

  1. Cut the two side screens from the layout. Each is 17.5 in (444.5 mm) ×5 in (127 mm). Flatten the edges; remove loose wires. Predrill wood before placing mesh; snip any fixing-station wire clearance behind the ring, without leaving exposed ends.
  2. Lay each screen against the inside side panel, with a half-inch margin around the opening. Place its one-piece ring over it.
  3. Fasten the ring at its six scheduled stations. Keep the buried points inside the outer panel and every cut wire end behind the ring.

Check before continuing: No loose mesh, projecting wire, trapped corner or contact with a front backer remains.

Watch out: Do not assume this mesh aperture suits every animal or feeder.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202630 / 108

Screens and final checks · 27 OF 32

27. Capture the roof screens

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Flat bench, mesh snips, W125 screws

Before you start: Work on each loose roof with its underside facing up.

Capture the roof screens. Picture explains the action; use the linked drawing for exact settings.

  1. Cut four 20 ×17 in (508 ×431.8 mm) screens. Position each with half-inch capture margins. Predrill wood before mesh; keep any snipped screw-station wire ends entirely behind the rings.
  2. Clamp the matching one-piece ring over each screen. Drive its six scheduled screws through clearance holes into the roof, without breaking the top face.
  3. Check the ring positions against rib and lap drawings. Keep equipment weight off the mesh.

Check before continuing: All four screens are flat, replaceable and clear of ribs/roof seams.

Watch out: Do not fasten a screen in place before its coating has fully cured.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202631 / 108

Screens and final checks · 28 OF 32

28. Fit the lift blocks, locks and pulls

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Delivered profiles, accepted sample, stopped drill, TRACK screws

Before you start: Every transferred hole must clear the glass and roller sweep.

Fit the lift blocks, locks and pulls. Picture explains the action; use the linked drawing for exact settings.

  1. Fit the eight HDPE lift blocks to the actual upper lanes. Use their removable web-only fixing stations; recorded trial dimensions govern their width/depth.
  2. At every door position, verify no more than 1/16 in lift and positive lower-shoe capture. Check lock clips cannot spread the leaves apart. Fit one 963L lock per bay and fourFP86 pulls by their instructions.
  3. Remove each lock body before sliding. Rehearse unlocking, removing lift blocks, lifting each pane out and refitting everything. Do not load the shell until the complete closure trial passes.

Check before continuing: Locks, lift prevention and the complete removal/refit path pass the actual trial.

Watch out: A keyed lock alone does not stop a pane lifting out of the tracks.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202632 / 108

Screens and final checks · 29 OF 32

29. Fit the removable roofs

Parts: Left roof P02L · Right roof P02R

Have ready: Helpers, W200 screws, hand driver, square

Before you start: Seat left roof first, then right. Do not glue them down.

Fit the removable roofs. Picture explains the action; use the linked drawing for exact settings.

  1. Set the LEFT lower tongue on the center rib. Lower the RIGHT upper tongue onto it; both outside faces finish level.
  2. Drive the eighteen listed roof screws into solid support lands, nine per half. Keep the center fixings outside the thin overlap.
  3. Check every seated edge gap and all screen/frame clearances. For service, remove screws and lift the right roof clear first; the fixed support frame remains in place.

Check before continuing: Both roofs seat flat and can be removed without disturbing the center post or ribs.

Watch out: The viewer’s hide-roof control is not permission to remove structural framing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202633 / 108

Screens and final checks · 30 OF 32

30. Seal the dry-basin seams

Parts: Floor P01 · Dry-bed retaining face P05 · L side P03L · R side P03R · Full back P04

Have ready: Selected DAP00688 silicone, accepted coating coupon, masking

Before you start: HOLD: DAP 00688 excludes use on or near zinc and galvanized metal. This build has zinc hardware. Resolve that conflict with the manufacturers, or revise the system and recheck it, before this operation.

Seal the dry-basin seams. Picture explains the action; use the linked drawing for exact settings.

  1. Proceed only after the documented corrosion-compatibility hold is closed. A coated screw head is not manufacturer approval.
  2. Only after full coating cure, clean and mask the dry-basin seams and lower fixed cleat edges. Use the exact accepted silicone formulation without substituting a mildew-additive product.
  3. Tool continuous nominal 1/4 in (6.35 mm) beads where the seam diagram identifies them. Seal penetrations without covering removable screen/roof parts or sliding channels.
  4. Keep a same-depth cutoff sample. Wait for full through-cure and verify adhesion to the actual coating; record dates and conditions.

Check before continuing: Seams are continuous and accepted samples are cured through, without peeling.

Watch out: A surface skin or an odor check does not establish through-cure.

Allow time: Reserve at least 7 days for the project seam/coupon hold; actual product, bead depth and conditions may require longer. This is a project hold, not an immersion approval.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202634 / 108

Screens and final checks · 31 OF 32

31. Check the installation before use

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Receiving/commissioning records, scales, straightedge, actual equipment instructions

Before you start: Do not add animals or contents until unresolved installation and use holds are resolved.

Check the installation before use. Picture explains the action; use the linked drawing for exact settings.

  1. Verify continuous flat support under the full 96 ×24 in floor. Measure the actual shell, dry bed and equipment mass; check the support and building floor separately. Obtain qualified review where inputs or capacities are uncertain.
  2. Check locks, lift prevention, gaps, exposed wire, fixings, coating and full opening/removal paths. Keep bed depth at or below 4 in (101.6 mm) and side vents unobstructed.
  3. Commission species/feeder containment, ventilation, humidity, protected heat and cable/electrical interfaces against their actual requirements. No species suitability, load capacity or heat clearance comes from this shell guide.

Check before continuing: Every required hold has evidence; prototype/physical/qualified status remains separate from digital checks.

Watch out: Average pounds per square foot does not approve a building floor.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202635 / 108

Screens and final checks · 32 OF 32

32. Clean, inspect and service the shell

Parts: Parts identified in the picture and linked workshop reference; complete IDs in the source schedule.

Have ready: Soft cleaning tools, accepted cleaner, replacement parts list

Before you start: Empty the shell and safely isolate equipment before service. Never move it filled.

Clean, inspect and service the shell. Picture explains the action; use the linked drawing for exact settings.

  1. Inspect glass edges, tracks, lock clips, lift blocks, screen capture, floor support and coatings regularly and after any equipment or loading change. Stop use if a joint loosens, support settles, glass catches or a finish fails.
  2. For glass service, remove the lock body and lift blocks before lifting an empty pane from its carrier. For roof service, remove the right half before the left; keep frame and ribs fixed.
  3. Clean only with the trial-approved method. Replace damaged screens/rings or worn closures with the same verified system; repair coating fully and allow cure before reuse. Record the work and the new acceptance checks.

Check before continuing: Parts remain replaceable and maintenance does not bypass the original fit, cure or containment checks.

Watch out: Do not slide, lift or relocate the filled assembly.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202636 / 108

Shopping list

Get ready

Shopping list

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Birch plywood PLY

712849 · purchased material

Buy 3 pack/stock unit(s), containing 3 sheet. Planned use/allowance 3; unused pack contents 0.

Three-sheet plan includes measured kerf and squaring. Minimum received envelope is derived in OP01; actual gauge/core/grain/defects must be checked.

Selected product and buying link

RELIABILT clear S4S solid pine SOLID

2X2 8 RPC · purchased material

Buy 5 pack/stock unit(s), containing 5 8 ft board. Planned use/allowance 5; unused pack contents 0.

Five 8 ft boards, full actual 1.5 x 1.5 in section. Sound stable straight stock; no thinning or narrow ripping.

Selected product and buying link

Acorn galvanized hardware cloth MESH

HC24810 · ventilation

Buy 1 pack/stock unit(s), containing 1 48 x 120 in roll. Planned use/allowance 1; unused pack contents 0.

Reference half-inch aperture and wire stack require receiving verification. Mesh is not containment for every animal/feeder. Six captures, wire edges protected.

Selected product and buying link

Titebond III Ultimate GLUE

1414 · adhesive

Buy 1 pack/stock unit(s), containing 1 16 fl oz bottle. Planned use/allowance 1; unused pack contents 0.

Titebond III on specified bare-wood joints only; do not use as a basin seal or certified structural adhesive.

Selected product and buying link

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202637 / 108

Get ready

Shopping list · continued

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Varathane Triple Thick clear satin water-based polyurethane FINISH

284473-7482 · finish

Buy 2 pack/stock unit(s), containing 4 quart. Planned use/allowance 4; unused pack contents 0.

Conservative coated wood area 147.14508 sq ft; extra two dry-basin coats 51.76562 sq ft. At published practical 50 sq ft/quart, 3.97821 quarts calculated. Purchase 4 quarts in two-quart packs. Each coat/recoat and final full cure follows OP21; no immersion or animal-contact test inferred.

Selected product and buying link

Loctite PL Premium construction adhesive TRACKBOND

1390595 · adhesive

Buy 1 pack/stock unit(s), containing 1 10 fl oz cartridge. Planned use/allowance 1; unused pack contents 0.

Matched steel-to-bare-wood bonds only. Actual coupon, controlled spacing, complete bracing and cure required at OP22. Not an HDPE or glass adhesive.

Selected product and buying link

DAP All Purpose 100% Silicone Rubber Adhesive Sealant, clear, 2.8 fl oz SEAL

00688 / 7079800755; Lowe’s six-pack 7079800755SOS · sealant

Buy 2 pack/stock unit(s), containing 12 2.8 fl oz tube. Planned use/allowance 8; unused pack contents 4.

Dry lower-seam and trial allowance: 54 ft at nominal quarter-inch bead plus 20 percent, eight tubes, purchase two six-packs. Exact DAP00688, coating adhesion and through-cure trial at OP30; no standing-water claim. HOLD: manufacturer excludes use on or near zinc/galvanized metal. This build contains zinc screws and tracks. Resolve before purchase/application.

Selected product and buying link

Rubber-Cal loose neoprene sheet PAD

30-004-062-012-036 · cushions

Buy 1 pack/stock unit(s), containing 1 12 x 36 in sheet. Planned use/allowance 1; unused pack contents 0.

Eight nominal 1/16 in jamb cushions, two lanes at four jambs. Transfer tab fixing outside glass travel after OP23 actual-profile trial.

Selected product and buying link

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202638 / 108

Get ready

Shopping list · continued

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Polymershapes smooth black high-density polyethylene (HDPE) sheet HDPE

51962104 · retention

Buy 1 pack/stock unit(s), containing 1 24 x 12 in sheet. Planned use/allowance 1; unused pack contents 0.

Eight nominal capture blocks, two per lane. Reference dimensions in cuts/layout; OP28 measures seated glazing and actual lane before sizing. Machine with a supported carrier; maximum lift 1/16 in while shoe remains captured.

Selected product and buying link

Kiln-dried untreated Douglas fir 2×4, select sound straight pieces RAIL

2x 4x 8KDDF · purchased material

Buy 2 pack/stock unit(s), containing 2 8 ft board. Planned use/allowance 2; unused pack contents 0.

Actual 1.5×3.5 in. Reject short studs, green/treated stock, wane, large knots at seats and warped boards. At least 95 in usable after end squaring.

Selected product and buying link

Roll-Ezy steel upper and jamb channel KV993

KV993 · sliding hardware

Buy 1 pack/stock unit(s), containing 1 144 in stock. Planned use/allowance 1; unused pack contents 0.

Derived cuts plus kerf 136.09375 in; use continuous rails, no butt joints. Receiving trials govern profile details.

Selected product and buying link

Roll-Ezy steel glass shoe KV995

KV995 · sliding hardware

Buy 1 pack/stock unit(s), containing 1 144 in stock. Planned use/allowance 1; unused pack contents 0.

Derived cuts plus kerf 91.96875 in; use continuous rails, no butt joints. Receiving trials govern profile details.

Selected product and buying link

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202639 / 108

Get ready

Shopping list · continued

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Roll-Ezy steel ball-bearing carrier KV997

KV997 · sliding hardware

Buy 1 pack/stock unit(s), containing 1 144 in stock. Planned use/allowance 1; unused pack contents 0.

Derived cuts plus kerf 135.76562 in; use continuous rails, no butt joints. Receiving trials govern profile details.

Selected product and buying link

Roll-Ezy steel lower track KV999

KV999 · sliding hardware

Buy 1 pack/stock unit(s), containing 1 144 in stock. Planned use/allowance 1; unused pack contents 0.

Derived cuts plus kerf 89.96875 in; use continuous rails, no butt joints. Receiving trials govern profile details.

Selected product and buying link

CRL chrome anti-spread ratchet lock for 1/4-inch glass LOCK

963L · hardware

Buy 2 pack/stock unit(s), containing 2 each. Planned use/allowance 2; unused pack contents 0.

Hardware model retained, quantities recalculated; no claim of local inventory or affiliate collection match.

Selected product and buying link

CRL silver plastic stick-on finger pull PULL

FP86 · hardware

Buy 1 pack/stock unit(s), containing 10 each. Planned use/allowance 4; unused pack contents 6.

Hardware model retained, quantities recalculated; no claim of local inventory or affiliate collection match.

Selected product and buying link

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202640 / 108

Get ready

Shopping list · continued

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Hillman #8 × 2-inch front-frame screws W200

35057 · hardware

Buy 2 pack/stock unit(s), containing 100 each. Planned use/allowance 84; unused pack contents 16.

Hardware model retained, quantities recalculated; no claim of local inventory or affiliate collection match.

Selected product and buying link

Hillman #8 × 1 1/4-inch shell screws W125

35054 · hardware

Buy 1 pack/stock unit(s), containing 100 each. Planned use/allowance 66; unused pack contents 34.

Hardware model retained, quantities recalculated; no claim of local inventory or affiliate collection match.

Selected product and buying link

Everbilt #4 × 3/4-inch Phillips flat-head wood screw, 12-pack TRACK

806891 · hardware

Buy 4 pack/stock unit(s), containing 48 each. Planned use/allowance 40; unused pack contents 8.

Hardware model retained, quantities recalculated; no claim of local inventory or affiliate collection match.

Selected product and buying link

Four polished-edge tempered scant 6 mm panes, no holes GLASS

local fabricator signed order · glazing

Buy 4 pack/stock unit(s), containing 4 pane. Planned use/allowance 4; unused pack contents 0.

Reference sizes only. Do not order before OP23 receiving/finished-frame trial. No cutting or drilling after tempering.

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202641 / 108

Get ready

Shopping list · continued

Exact products and purchase packs are listed separately from installed quantities. Confirm delivery and local availability. Substitutions may change geometry, exposure limits or capacity.

Abrasives 120/220, brushes, masking, glue cleanup, trial offcuts CONSUMABLES

shop selection · consumables

Buy 1 pack/stock unit(s), containing 1 allowance. Planned use/allowance 1; unused pack contents 0.

No precision cost or consumption claim. Reserve offcuts; include tool wear and handling separately.

Animal/equipment configuration excluded EQUIPMENT

separate documented design · optional

Buy 0 pack/stock unit(s), containing 0 not included. Planned use/allowance 0; unused pack contents 0.

No heater, lighting, stand, habitat or animal safety is inferred.

No location-qualified total price is claimed. Add taxes, delivery, consumables, tool wear and actual labor. The full wooden parts schedule is separate from purchased stock.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202642 / 108

Cut list

Prepare the parts

Cut list

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
P01
Floor
PLY
45/64 in (17.86 mm)
96 in (2438.4 mm) × 24 in (609.6 mm)
96 1/16 in (2439.99 mm) × 24 1/32 in (610.39 mm)
P03L
L side
PLY
45/64 in (17.86 mm)
22 19/32 in (573.88 mm) × 24 in (609.6 mm)
22 21/32 in (575.47 mm) × 24 1/32 in (610.39 mm)
P03R
R side
PLY
45/64 in (17.86 mm)
22 19/32 in (573.88 mm) × 24 in (609.6 mm)
22 21/32 in (575.47 mm) × 24 1/32 in (610.39 mm)
P04
Full back
PLY
45/64 in (17.86 mm)
94 19/32 in (2402.68 mm) × 22 19/32 in (573.88 mm)
94 21/32 in (2404.27 mm) × 22 5/8 in (574.67 mm)
P05
Dry-bed retaining face
PLY
45/64 in (17.86 mm)
94 19/32 in (2402.68 mm) × 6 in (152.4 mm)
94 21/32 in (2404.27 mm) × 6 1/32 in (153.19 mm)
B1U
Post 1 upper backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)
B1D
Post 1 lower backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202643 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
B2U
Post 2 upper backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)
B2D
Post 2 lower backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)
B3U
Post 3 upper backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)
B3D
Post 3 lower backer
PLY
45/64 in (17.86 mm)
4 in (101.6 mm) × 1 1/2 in (38.1 mm)
4 1/16 in (103.19 mm) × 1 17/32 in (38.89 mm)
P02L
Left roof
PLY
45/64 in (17.86 mm)
48 1/4 in (1225.55 mm) × 24 in (609.6 mm)
48 5/16 in (1227.14 mm) × 24 1/32 in (610.39 mm)
P02R
Right roof
PLY
45/64 in (17.86 mm)
48 1/4 in (1225.55 mm) × 24 in (609.6 mm)
48 5/16 in (1227.14 mm) × 24 1/32 in (610.39 mm)
V01L
L side screen ring
PLY
45/64 in (17.86 mm)
18 in (457.2 mm) × 5 1/2 in (139.7 mm)
18 1/16 in (458.79 mm) × 5 17/32 in (140.49 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202644 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
V01R
R side screen ring
PLY
45/64 in (17.86 mm)
18 in (457.2 mm) × 5 1/2 in (139.7 mm)
18 1/16 in (458.79 mm) × 5 17/32 in (140.49 mm)
V021
Roof screen ring 1
PLY
45/64 in (17.86 mm)
20 1/2 in (520.7 mm) × 17 1/2 in (444.5 mm)
20 9/16 in (522.29 mm) × 17 17/32 in (445.29 mm)
V022
Roof screen ring 2
PLY
45/64 in (17.86 mm)
20 1/2 in (520.7 mm) × 17 1/2 in (444.5 mm)
20 9/16 in (522.29 mm) × 17 17/32 in (445.29 mm)
V023
Roof screen ring 3
PLY
45/64 in (17.86 mm)
20 1/2 in (520.7 mm) × 17 1/2 in (444.5 mm)
20 9/16 in (522.29 mm) × 17 17/32 in (445.29 mm)
V024
Roof screen ring 4
PLY
45/64 in (17.86 mm)
20 1/2 in (520.7 mm) × 17 1/2 in (444.5 mm)
20 9/16 in (522.29 mm) × 17 17/32 in (445.29 mm)
S01
Front sill
RAIL
1 1/2 in (38.1 mm)
94 19/32 in (2402.68 mm) × 3 1/2 in (88.9 mm)
94 21/32 in (2404.27 mm) × 3 1/2 in (88.9 mm)
S02
Front header
RAIL
1 1/2 in (38.1 mm)
94 19/32 in (2402.68 mm) × 3 1/2 in (88.9 mm)
94 21/32 in (2404.27 mm) × 3 1/2 in (88.9 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202645 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
S101
Sill support block 1
SOLID
1 1/2 in (38.1 mm)
2 1/2 in (63.5 mm) × 1 1/2 in (38.1 mm)
2 9/16 in (65.09 mm) × 1 1/2 in (38.1 mm)
S102
Sill support block 2
SOLID
1 1/2 in (38.1 mm)
2 1/2 in (63.5 mm) × 1 1/2 in (38.1 mm)
2 9/16 in (65.09 mm) × 1 1/2 in (38.1 mm)
S103
Sill support block 3
SOLID
1 1/2 in (38.1 mm)
2 1/2 in (63.5 mm) × 1 1/2 in (38.1 mm)
2 9/16 in (65.09 mm) × 1 1/2 in (38.1 mm)
S104
Sill support block 4
SOLID
1 1/2 in (38.1 mm)
2 1/2 in (63.5 mm) × 1 1/2 in (38.1 mm)
2 9/16 in (65.09 mm) × 1 1/2 in (38.1 mm)
S105
Sill support block 5
SOLID
1 1/2 in (38.1 mm)
2 1/2 in (63.5 mm) × 1 1/2 in (38.1 mm)
2 9/16 in (65.09 mm) × 1 1/2 in (38.1 mm)
S201
Front post 1
SOLID
1 1/2 in (38.1 mm)
13 3/32 in (332.58 mm) × 1 1/2 in (38.1 mm)
13 5/32 in (334.17 mm) × 1 1/2 in (38.1 mm)
S202
Front post 2
SOLID
1 1/2 in (38.1 mm)
13 3/32 in (332.58 mm) × 1 1/2 in (38.1 mm)
13 5/32 in (334.17 mm) × 1 1/2 in (38.1 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202646 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
S203
Front post 3
SOLID
1 1/2 in (38.1 mm)
13 3/32 in (332.58 mm) × 1 1/2 in (38.1 mm)
13 5/32 in (334.17 mm) × 1 1/2 in (38.1 mm)
S30L
L rear corner post
SOLID
1 1/2 in (38.1 mm)
22 19/32 in (573.88 mm) × 1 1/2 in (38.1 mm)
22 21/32 in (575.47 mm) × 1 1/2 in (38.1 mm)
S40LB
L lower side cleat
SOLID
1 1/2 in (38.1 mm)
19 19/32 in (497.68 mm) × 1 1/2 in (38.1 mm)
19 21/32 in (499.27 mm) × 1 1/2 in (38.1 mm)
S40LT
L upper side cleat
SOLID
1 1/2 in (38.1 mm)
19 19/32 in (497.68 mm) × 1 1/2 in (38.1 mm)
19 21/32 in (499.27 mm) × 1 1/2 in (38.1 mm)
S30R
R rear corner post
SOLID
1 1/2 in (38.1 mm)
22 19/32 in (573.88 mm) × 1 1/2 in (38.1 mm)
22 21/32 in (575.47 mm) × 1 1/2 in (38.1 mm)
S40RB
R lower side cleat
SOLID
1 1/2 in (38.1 mm)
19 19/32 in (497.68 mm) × 1 1/2 in (38.1 mm)
19 21/32 in (499.27 mm) × 1 1/2 in (38.1 mm)
S40RT
R upper side cleat
SOLID
1 1/2 in (38.1 mm)
19 19/32 in (497.68 mm) × 1 1/2 in (38.1 mm)
19 21/32 in (499.27 mm) × 1 1/2 in (38.1 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202647 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
S50B
Lower back rail
SOLID
1 1/2 in (38.1 mm)
91 19/32 in (2326.48 mm) × 1 1/2 in (38.1 mm)
91 21/32 in (2328.07 mm) × 1 1/2 in (38.1 mm)
S50T
Upper back rail
SOLID
1 1/2 in (38.1 mm)
91 19/32 in (2326.48 mm) × 1 1/2 in (38.1 mm)
91 21/32 in (2328.07 mm) × 1 1/2 in (38.1 mm)
S51
Center back post
SOLID
1 1/2 in (38.1 mm)
19 19/32 in (497.68 mm) × 1 1/2 in (38.1 mm)
19 21/32 in (499.27 mm) × 1 1/2 in (38.1 mm)
S601
Roof rib 1
SOLID
1 1/2 in (38.1 mm)
20 19/32 in (523.08 mm) × 1 1/2 in (38.1 mm)
20 21/32 in (524.67 mm) × 1 1/2 in (38.1 mm)
S602
Roof rib 2
SOLID
1 1/2 in (38.1 mm)
20 19/32 in (523.08 mm) × 1 1/2 in (38.1 mm)
20 21/32 in (524.67 mm) × 1 1/2 in (38.1 mm)
S603
Roof rib 3
SOLID
1 1/2 in (38.1 mm)
20 19/32 in (523.08 mm) × 1 1/2 in (38.1 mm)
20 21/32 in (524.67 mm) × 1 1/2 in (38.1 mm)
T1U
Bay 1 upper rail
KV993
15/16 in (23.81 mm)
44 59/64 in (1141.02 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202648 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
T1L
Bay 1 lower rail
KV999
1 in (25.4 mm)
44 59/64 in (1141.02 mm) × 1 in (25.4 mm)
Receiving checkpoint
OP23 / OP28
T1JL
Bay 1 L jamb channel
KV993
15/16 in (23.81 mm)
11 13/32 in (289.72 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28
T1JR
Bay 1 R jamb channel
KV993
15/16 in (23.81 mm)
11 13/32 in (289.72 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28
G1L
Bay 1 L glass
GLASS
0.23622 in (6 mm)
22.89844 in (581.62 mm) × 11 25/32 in (299.24 mm)
Receiving checkpoint
OP23 / OP28
D1LS
Bay 1 L shoe
KV995
21/64 in (8.33 mm)
22.89844 in (581.62 mm) × 7/16 in (11.11 mm)
Receiving checkpoint
OP23 / OP28
D1LC
Bay 1 L carrier
KV997
3/8 in (9.52 mm)
33.84766 in (859.73 mm) × 17/32 in (13.49 mm)
Receiving checkpoint
OP23 / OP28
A1L1
Bay 1 L lift block 1
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202649 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
A1L2
Bay 1 L lift block 2
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
G1R
Bay 1 R glass
GLASS
0.23622 in (6 mm)
22.89844 in (581.62 mm) × 11 25/32 in (299.24 mm)
Receiving checkpoint
OP23 / OP28
D1RS
Bay 1 R shoe
KV995
21/64 in (8.33 mm)
22.89844 in (581.62 mm) × 7/16 in (11.11 mm)
Receiving checkpoint
OP23 / OP28
D1RC
Bay 1 R carrier
KV997
3/8 in (9.52 mm)
33.84766 in (859.73 mm) × 17/32 in (13.49 mm)
Receiving checkpoint
OP23 / OP28
A1R1
Bay 1 R lift block 1
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
A1R2
Bay 1 R lift block 2
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
C1LL
Bay 1 L cushion L
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202650 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
C1LR
Bay 1 L cushion R
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
C1RL
Bay 1 R cushion L
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
C1RR
Bay 1 R cushion R
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
T2U
Bay 2 upper rail
KV993
15/16 in (23.81 mm)
44 59/64 in (1141.02 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28
T2L
Bay 2 lower rail
KV999
1 in (25.4 mm)
44 59/64 in (1141.02 mm) × 1 in (25.4 mm)
Receiving checkpoint
OP23 / OP28
T2JL
Bay 2 L jamb channel
KV993
15/16 in (23.81 mm)
11 13/32 in (289.72 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28
T2JR
Bay 2 R jamb channel
KV993
15/16 in (23.81 mm)
11 13/32 in (289.72 mm) × 5/8 in (15.88 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202651 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
G2L
Bay 2 L glass
GLASS
0.23622 in (6 mm)
22.89844 in (581.62 mm) × 11 25/32 in (299.24 mm)
Receiving checkpoint
OP23 / OP28
D2LS
Bay 2 L shoe
KV995
21/64 in (8.33 mm)
22.89844 in (581.62 mm) × 7/16 in (11.11 mm)
Receiving checkpoint
OP23 / OP28
D2LC
Bay 2 L carrier
KV997
3/8 in (9.52 mm)
33.84766 in (859.73 mm) × 17/32 in (13.49 mm)
Receiving checkpoint
OP23 / OP28
A2L1
Bay 2 L lift block 1
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
A2L2
Bay 2 L lift block 2
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
G2R
Bay 2 R glass
GLASS
0.23622 in (6 mm)
22.89844 in (581.62 mm) × 11 25/32 in (299.24 mm)
Receiving checkpoint
OP23 / OP28
D2RS
Bay 2 R shoe
KV995
21/64 in (8.33 mm)
22.89844 in (581.62 mm) × 7/16 in (11.11 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202652 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
D2RC
Bay 2 R carrier
KV997
3/8 in (9.52 mm)
33.84766 in (859.73 mm) × 17/32 in (13.49 mm)
Receiving checkpoint
OP23 / OP28
A2R1
Bay 2 R lift block 1
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
A2R2
Bay 2 R lift block 2
HDPE
5/16 in (7.94 mm)
22.39844 in (568.92 mm) × 11/32 in (8.73 mm)
Receiving checkpoint
OP23 / OP28
C2LL
Bay 2 L cushion L
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
C2LR
Bay 2 L cushion R
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
C2RL
Bay 2 R cushion L
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28
C2RR
Bay 2 R cushion R
PAD
1/16 in (1.59 mm)
11 13/32 in (289.72 mm) × 0.28 in (7.11 mm)
Receiving checkpoint
OP23 / OP28

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202653 / 108

Prepare the parts

Cut list · continued

One of each ID. Read u/v from the named part drawing. Finished sizes govern; blanks include their stated finishing allowance. Saw kerf falls between blanks. Reference hardware/glass sizes remain on hold until the named receiving checkpoint.

Part / materialThicknessFinished u × vRough u × v
M01L
L side mesh
MESH
0.025 in (0.64 mm)
17 1/2 in (444.5 mm) × 5 in (127 mm)
17.5 × 5 in
(444.5 × 127 mm)
M01R
R side mesh
MESH
0.025 in (0.64 mm)
17 1/2 in (444.5 mm) × 5 in (127 mm)
17.5 × 5 in
(444.5 × 127 mm)
M021
Roof mesh 1
MESH
0.025 in (0.64 mm)
20 in (508 mm) × 17 in (431.8 mm)
20 × 17 in
(508 × 431.8 mm)
M022
Roof mesh 2
MESH
0.025 in (0.64 mm)
20 in (508 mm) × 17 in (431.8 mm)
20 × 17 in
(508 × 431.8 mm)
M023
Roof mesh 3
MESH
0.025 in (0.64 mm)
20 in (508 mm) × 17 in (431.8 mm)
20 × 17 in
(508 × 431.8 mm)
M024
Roof mesh 4
MESH
0.025 in (0.64 mm)
20 in (508 mm) × 17 in (431.8 mm)
20 × 17 in
(508 × 431.8 mm)

Plywood panel target±1/64 in; matched members within 0.010 in. Joint depths±0.005 in. These are project shop targets, not allowable capacities. Received profiles, glazing tolerance and the cured roof sample govern their own fits. The CSV also retains faces, grain, machining, holes, handedness and assembly references.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202654 / 108

Cutting diagrams

Prepare the parts

Cutting layout · PLY-1

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202655 / 108

Prepare the parts

Cutting layout · PLY-2

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202656 / 108

Prepare the parts

Cutting layout · PLY-3

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202657 / 108

Prepare the parts

Cutting layout · RAIL

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202658 / 108

Prepare the parts

Cutting layout · SOLID

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202659 / 108

Prepare the parts

Cutting layout · MESH

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202660 / 108

Prepare the parts

Cutting layout · HDPE

This is a feasible cutting sequence, not an optimization claim. Measure stock and kerf first; reject defects in required blanks.

Keep the marked grain direction and part IDs. Use supported cuts; small pieces need a carrier. Received hardware and trial pieces are checked before final sizing.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202661 / 108

Prepare the parts

Steel section layout · KV993

Each uses one 144 in stock length in this reference configuration. Actual metal kerf, final frame measurements and profile compatibility govern acceptance.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202662 / 108

Prepare the parts

Steel section layout · KV995

Each uses one 144 in stock length in this reference configuration. Actual metal kerf, final frame measurements and profile compatibility govern acceptance.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202663 / 108

Prepare the parts

Steel section layout · KV997

Each uses one 144 in stock length in this reference configuration. Actual metal kerf, final frame measurements and profile compatibility govern acceptance.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202664 / 108

Prepare the parts

Steel section layout · KV999

Each uses one 144 in stock length in this reference configuration. Actual metal kerf, final frame measurements and profile compatibility govern acceptance.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202665 / 108

Workshop drawings and measurements

Use the exact workshop references

Workshop reference

Step pictures explain the action. These drawings and schedules define sizes and locations. They are not printable sizing templates. Never measure a printed picture to make a part.

Mark / termMeaning
A / B
A outward/show face; B inside. Keep FRONT/BOTTOM labels when turning a piece.
u 0 / v 0
The two finished local measuring edges shown on each drawing. Measure every location from those datums.
X / Y / Z
X right; Y toward back; Z upward, facing the access front.
Blue recess / white opening
Blue removes only stated depth; a white opening goes through full material.
C / P
Clearance through first wood; smaller pilot transferred into receiver during clamped fit.
Entry axis + / −
Drill direction in assembly axes; identify the physical starting face before drilling.
Exact versus reference
Finished wood cuts are exact source values with project tolerance. Hardware and glazing reference geometry needs the identified receiving trial.
Field fit
OP23 measures actual cured track outside faces and cushioned stops; OP28 sizes actual capture blocks. The documented equations replace an unspecified “cut to fit.”

Full cut-list and fastener CSV files retain exact values. Changing material thickness or hardware invalidates them, the drawings, model, illustrations and guide.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202666 / 108

Workshop drawing · Overall

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202667 / 108

Workshop drawing · Side

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202668 / 108

Workshop drawing · Exploded

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202669 / 108

Workshop drawing · Front Frame

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202670 / 108

Workshop drawing · Back Joint

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202671 / 108

Workshop drawing · Rib Seat

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202672 / 108

Workshop drawing · Roof Joint

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202673 / 108

Workshop drawing · Screen Section

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202674 / 108

Workshop drawing · Track Fit

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202675 / 108

Workshop drawing · Retention Service

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202676 / 108

Workshop drawing · Workholding

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202677 / 108

Workshop drawing · Finish Route

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202678 / 108

Workshop drawing · Floor P01

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202679 / 108

Workshop drawing · Left roof P02L

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202680 / 108

Workshop drawing · Right roof P02R

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202681 / 108

Workshop drawing · L side P03L

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202682 / 108

Workshop drawing · R side P03R

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202683 / 108

Workshop drawing · Full back P04

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202684 / 108

Workshop drawing · Dry-bed retaining face P05

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202685 / 108

Workshop drawing · Front header S02

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202686 / 108

Workshop drawing · Upper back rail S50T

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202687 / 108

Workshop drawing · Roof rib 1 S601

Workshop reference

Revision v 5-square-back-02. The complete part drawing set is available in the drawings download. Product contours and temporary tools are explanatory where labeled.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202688 / 108

Exact drilling schedule

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX001
P03L→S30L
4 / 22.54688
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX002
P03L→S30L
11 / 22.54688
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX003
P03L→S30L
18 / 22.54688
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX004
P03L→S40LB
0.75 / 4.20312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX005
P03L→S40LB
0.75 / 12
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX006
P03L→S40LB
0.75 / 19.79688
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX007
P03L→S40LT
21.84375 / 4.20312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX008
P03L→S40LT
21.84375 / 12
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX009
P03L→S40LT
21.84375 / 19.79688
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX010
P03L→S201
9 / 1.45312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX011
P03L→S201
15 / 1.45312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX012
P03L→S01
4.25 / 1.45312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX013
P03L→S02
20.84375 / 1.45312
X+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX014
P03R→S30R
4 / 22.54688
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX015
P03R→S30R
11 / 22.54688
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202689 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX016
P03R→S30R
18 / 22.54688
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX017
P03R→S40RB
0.75 / 4.20312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX018
P03R→S40RB
0.75 / 12
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX019
P03R→S40RB
0.75 / 19.79688
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX020
P03R→S40RT
21.84375 / 4.20312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX021
P03R→S40RT
21.84375 / 12
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX022
P03R→S40RT
21.84375 / 19.79688
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX023
P03R→S203
9 / 1.45312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX024
P03R→S203
15 / 1.45312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX025
P03R→S01
4.25 / 1.45312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX026
P03R→S02
20.84375 / 1.45312
X−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX027
P01→S40LB
1.45312 / 4.20312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX028
P01→S40LB
1.45312 / 19.79688
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX029
P01→S40RB
94.54688 / 4.20312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX030
P01→S40RB
94.54688 / 19.79688
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202690 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX031
P01→S30L
1.45312 / 22.54688
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX032
P01→S30R
94.54688 / 22.54688
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX033
P01→S101
1.45312 / 1.45312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX034
P01→S102
25 / 1.45312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX035
P01→S103
48 / 1.45312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX036
P01→S104
71 / 1.45312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX037
P01→S105
94.54688 / 1.45312
Z+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX038
P04→S30L
0.75 / 3
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX039
P04→S30L
0.75 / 9
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX040
P04→S30L
0.75 / 15
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX041
P04→S30L
0.75 / 21
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX042
P04→S30R
93.84375 / 3
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX043
P04→S30R
93.84375 / 9
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX044
P04→S30R
93.84375 / 15
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX045
P04→S30R
93.84375 / 21
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202691 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX046
P04→S51
47.29688 / 5
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX047
P04→S51
47.29688 / 11
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX048
P04→S51
47.29688 / 17
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX049
P04→S50B
7.29688 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX050
P04→S50B
31.29688 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX051
P04→S50B
55.29688 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX052
P04→S50B
79.29688 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX053
P04→S50T
7.29688 / 21.84375
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX054
P04→S50T
31.29688 / 21.84375
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX055
P04→S50T
55.29688 / 21.84375
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX056
P04→S50T
79.29688 / 21.84375
Y−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX057
P05→S101
0.75 / 1.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX058
P05→S102
24.29688 / 1.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX059
P05→S103
47.29688 / 1.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX060
P05→S104
70.29688 / 1.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202692 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX061
P05→S105
93.84375 / 1.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX062
P05→S01
2 / 4.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX063
P05→S01
24.29688 / 4.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX064
P05→S01
47.29688 / 4.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX065
P05→S01
70.29688 / 4.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX066
P05→S01
92.59375 / 4.25
Y+
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX067
B1U→S201
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX068
B1U→S201
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX069
B1U→S02
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX070
B1U→S02
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX071
B1D→S01
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX072
B1D→S01
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX073
B1D→S201
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX074
B1D→S201
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX075
B2U→S202
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202693 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX076
B2U→S202
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX077
B2U→S02
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX078
B2U→S02
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX079
B2D→S01
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX080
B2D→S01
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX081
B2D→S202
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX082
B2D→S202
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX083
B3U→S203
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX084
B3U→S203
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX085
B3U→S02
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX086
B3U→S02
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX087
B3D→S01
0.75 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX088
B3D→S01
1.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX089
B3D→S203
2.5 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25
FX090
B3D→S203
3.25 / 0.75
Y−
0.17188 × 0.70312
0.10938 × 0.57812
W125
1.25

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202694 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX091
S601→S02
0.25 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX092
S601→S50T
20.34375 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX093
S602→S02
0.25 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX094
S602→S50T
20.34375 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX095
S603→S02
0.25 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX096
S603→S50T
20.34375 / 0.75
Z−
0.17188 × 0.75
0.10938 × 0.53125
W125
1.25
FX097
P02L→S02
5 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX098
P02L→S02
20 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX099
P02L→S02
38 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX100
P02L→S50T
5 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX101
P02L→S50T
20 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX102
P02L→S50T
38 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX103
P02L→S40LT
1.45312 / 7
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX104
P02L→S40LT
1.45312 / 17
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX105
P02L→S602
47.5 / 12
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202695 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX106
P02R→S02
10.25 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX107
P02R→S02
28.25 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX108
P02R→S02
43.25 / 1.45312
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX109
P02R→S50T
10.25 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX110
P02R→S50T
28.25 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX111
P02R→S50T
43.25 / 22.54688
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX112
P02R→S40RT
46.79688 / 7
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX113
P02R→S40RT
46.79688 / 17
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX114
P02R→S602
0.75 / 12
Z−
0.17188 × 0.70312
0.10938 × 1.32812
W200
2
FX115
V01L→P03L
0.375 / 0.375
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX116
V01L→P03L
17.625 / 0.375
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX117
V01L→P03L
0.375 / 5.125
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX118
V01L→P03L
17.625 / 5.125
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX119
V01L→P03L
9 / 0.375
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX120
V01L→P03L
9 / 5.125
X−
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202696 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX121
V01R→P03R
0.375 / 0.375
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX122
V01R→P03R
17.625 / 0.375
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX123
V01R→P03R
0.375 / 5.125
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX124
V01R→P03R
17.625 / 5.125
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX125
V01R→P03R
9 / 0.375
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX126
V01R→P03R
9 / 5.125
X+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX127
V021→P02L
0.375 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX128
V021→P02L
20.125 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX129
V021→P02L
0.375 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX130
V021→P02L
20.125 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX131
V021→P02L
10.25 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX132
V021→P02L
10.25 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX133
V022→P02L
0.375 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX134
V022→P02L
20.125 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX135
V022→P02L
0.375 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202697 / 108

Exact drilling schedule · continued

Workshop reference

All sizes below are inches. u/v are from the first piece’s finished drawing edges. C is diameter × through-stack depth; P is trial starting diameter × receiver-pilot depth. Receiver holes are transferred while clamped. C may include captured mesh spacing; predrill wood before adding wire.

ID / first→receiveru / vEntryC Ø × depthP Ø × depthScrew / length
FX136
V022→P02L
20.125 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX137
V022→P02L
10.25 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX138
V022→P02L
10.25 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX139
V023→P02R
0.375 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX140
V023→P02R
20.125 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX141
V023→P02R
0.375 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX142
V023→P02R
20.125 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX143
V023→P02R
10.25 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX144
V023→P02R
10.25 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX145
V024→P02R
0.375 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX146
V024→P02R
20.125 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX147
V024→P02R
0.375 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX148
V024→P02R
20.125 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX149
V024→P02R
10.25 / 0.375
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25
FX150
V024→P02R
10.25 / 17.125
Z+
0.17188 × 0.72813
0.10938 × 0.55312
W125
1.25

Countersink flush only after the offcut trial. Metal/HDPE/cushion web holes are separate receiving transfers, not invented manufacturer patterns. Use the exact source CSV for global coordinates and all transfer limits.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202698 / 108

Exact openings and recesses

Workshop reference

Inches. Coordinates are local u/v from each named drawing, with depth along its normal. Use its face label; a roof lap and a rib notch remove different faces.

Part / featureu / v startu × v sizeDepthOperation
P03L
side-vent-L
7 / 3.75
4 × 16.5
0.70312
through side vent
P03R
side-vent-R
7 / 3.75
4 × 16.5
0.70312
through side vent
P02L
P02L-lap
47.75 / 0
0.5 × 24
0.36156
complementary roof overlap with finish-fit allowance
P02L
P02L-vent 1
4 / 4
19 × 16
0.70312
through roof vent
P02L
P02L-vent 2
27 / 4
19 × 16
0.70312
through roof vent
P02R
P02R-lap
0 / 0
0.5 × 24
0.36156
complementary roof overlap with finish-fit allowance
P02R
P02R-vent 1
2.25 / 4
19 × 16
0.70312
through roof vent
P02R
P02R-vent 2
25.25 / 4
19 × 16
0.70312
through roof vent
V01L
V01L-opening
0.75 / 0.75
16.5 × 4
0.70312
through opening
V01R
V01R-opening
0.75 / 0.75
16.5 × 4
0.70312
through opening
V021
V021-opening
0.75 / 0.75
19 × 16
0.70312
through opening
V022
V022-opening
0.75 / 0.75
19 × 16
0.70312
through opening
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 202699 / 108

Exact openings and recesses

Workshop reference

Inches. Coordinates are local u/v from each named drawing, with depth along its normal. Use its face label; a roof lap and a rib notch remove different faces.

Part / featureu / v startu × v sizeDepthOperation
V023
V023-opening
0.75 / 0.75
19 × 16
0.70312
through opening
V024
V024-opening
0.75 / 0.75
19 × 16
0.70312
through opening
S02
S02-seat 1
23.54688 / 2.75
1.5 × 0.75
0.5
roof-rib bearing seat
S02
S02-seat 2
46.54688 / 2.75
1.5 × 0.75
0.5
roof-rib bearing seat
S02
S02-seat 3
69.54688 / 2.75
1.5 × 0.75
0.5
roof-rib bearing seat
S50T
S50T-seat 1
22.04688 / 0.75
1.5 × 0.75
0.5
roof-rib bearing seat
S50T
S50T-seat 2
45.04688 / 0.75
1.5 × 0.75
0.5
roof-rib bearing seat
S50T
S50T-seat 3
68.04688 / 0.75
1.5 × 0.75
0.5
roof-rib bearing seat
S601
rib-front-1
0 / 0
0.5 × 1.5
0.75
lower end notch
S601
rib-back-1
20.09375 / 0
0.5 × 1.5
0.75
lower end notch
S602
rib-front-2
0 / 0
0.5 × 1.5
0.75
lower end notch
S602
rib-back-2
20.09375 / 0
0.5 × 1.5
0.75
lower end notch
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026100 / 108

Exact openings and recesses

Workshop reference

Inches. Coordinates are local u/v from each named drawing, with depth along its normal. Use its face label; a roof lap and a rib notch remove different faces.

Part / featureu / v startu × v sizeDepthOperation
S603
rib-front-3
0 / 0
0.5 × 1.5
0.75
lower end notch
S603
rib-back-3
20.09375 / 0
0.5 × 1.5
0.75
lower end notch
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026101 / 108

Part detail · Lower back rail S50B

Workshop reference

Use the exact cut/machining/fastener schedules, not a measurement of this picture.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026106 / 108

Part detail · L side screen ring V01L

Workshop reference

Use the exact cut/machining/fastener schedules, not a measurement of this picture.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026107 / 108

Part detail · R side screen ring V01R

Workshop reference

Use the exact cut/machining/fastener schedules, not a measurement of this picture.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026108 / 108

Workshop reference

Finishing, adhesives and moisture limits

Structural bearing/fasteners, wood glue, metal-track adhesive, decorative coating and seam sealant have different jobs. None independently certifies the enclosure.

Product / roleRequired process / limitation
Titebond III1414, bare wood joints
Above 47°F application;8–10 min open/20–25 min total at 70°F/50%RH. Tight seated joints, stressed clamp hold 24 h. Manufacturer excludes certified structural/load-bearing and continuous submersion. No allowable bond strength is used.
PL Premium 1390595, wood–zinc tracks
Clean bare wood/metal, continuous aligned bond,≥24 h bracing and 48 h project loading hold at 78°F/50%RH, longer in cold/dry conditions. Actual bonded-profile coupon required. Not HDPE adhesive, tank liner or rolling-lane filler.
Varathane 284473, dry interior coating
120→220 preparation, dust removal, stir, synthetic brush;9 mil wet/3 mil dry;50sqft/quart published practical coverage.2 h recoat/48 h light handling/7 days full cure at 70°F/50%RH. No immersion, outdoor or floor-wear approval. Delivered label controls.
DAP00688 exact clear silicone, dry seams
HOLD for zinc/galvanized-metal exclusion; written disposition or revised system required. Coating-adhesion and same-depth cure sample required; nominal 1/4 in beads,≥7 day project hold. No mildew-additive substitution or water-tank approval.
Coverage / purchasing
Derived finish-area ceiling 147.14508sqft; extra basin-coat allowance 51.76562sqft. At 50sqft/quart: 3.97821quarts, buy 4. Sealant planning ceiling 54 ft plus 20%: eight 2.8 fl oz tubes, buy two 6-packs.

The owner’s finish decision permits this dry/moderate-humidity research scope. It is not an animal-contact, abrasion, cleaner or leak test. Stop use if coatings wear, seams peel or wood swells. These questions need actual intended-use evidence.

N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026102 / 108

Inspection records

Records

Record receiving and trials

Blank fields are intentional. Reference values and digital checks are not receiving or physical measurements.

Check / recordActual result and evidence
Sheet batch/core/thickness range; minimum usable sheet dimensions
____________________________
Each solid section, straightness, sound seats and stable moisture readings
____________________________
Actual wood and metal kerfs; stock/defect plan
____________________________
#8 and #4 root/pilot/countersink trials; remaining wood
____________________________
Coated roof fit sample; actual measured gap
____________________________
Matched KV models, lane geometry, cushions, signed glass order
____________________________
Track bond coupon, cure dates and alignment
____________________________
Lift/capture/lock/stop/removal trial; supplier confirmation for changes
____________________________
Finish/cleaner/adhesion and seam through-cure coupons
____________________________
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026103 / 108

Records

Installation and maintenance record

Blank fields are intentional. Reference values and digital checks are not receiving or physical measurements.

Check / recordActual result and evidence
Actual shell/bed/equipment mass and maximum bed depth
____________________________
Support footprint, flatness, settlement and capacity evidence
____________________________
Building-floor/site and required qualified-review disposition
____________________________
Closure/gaps/wire/fasteners/cured coatings inspection
____________________________
Species/feeder containment, airflow/humidity and equipment commissioning
____________________________
Prototype built: separate evidence or NOT PERFORMED
____________________________
Physical tests: separate evidence or NOT PERFORMED
____________________________
Qualified review: exact scope or NOT PERFORMED
____________________________
Maintenance date, fault, replacement part and acceptance result
____________________________
N11 · v5-square-back-02 · illustrated-02 · Revised 4 Oct 2026104 / 108

Product sources and validation status

References

Source evidence accompanies the private review. Original manufacturer instructions for the delivered model govern. Access date 3 October 2026.

QuestionOriginal source
Matched steel hardware
KV300807-A/0110 installation; OL2255/1016 specification. Outer sections/equations are documented; PDF metric conversion errors are corrected by deriving from inches.
Current kit scope
KV P992 kit. Candidate panes are below its 36 in description; completed-assembly suitability remains untested.
Lock / pulls
CRL963L; CRLFP86. Exact verified full product URLs are in the BOM.
Glue / finish / track bond
Wood science and calculation boundaries
V5 topics 02/04/07 and USDA2021 Wood Handbook, chapters 4/5/8/11. No laboratory property has been treated as an allowable capacity.

Owner-authorized square-back revision, 4 October 2026. Research, dimensional checks, bounded calculations and digital checks have separate evidence records. Prototype construction, physical testing and qualified review are NOT PERFORMED. Website publication is recorded separately. Unknown stock/hardware/support/intended-use inputs block an unconditional construction or capacity claim.

Build nb 20260929-n 11 · v 5-square-back-02 · illustrated-02

Source SHA256 e 2bfe 02531ebb 93ef 07eb 3e 4adef 511cb 1b 29f 909249c 51e 9421b 8fa 4450047f

Enlarged construction picture